1.Main characteristics
* Meets all the requirement of field tests. This tester with standard 4 phase voltage, 3 phase current output, voltage 125V/phase, current 40A/phase, 3 phases in parallel can up to 120A. Digital Signal Processor Microcomputer. Not only test the traditional relays and protectors, but also test the modern micro computer replays, special for transformer differential protection and transfer equipments
* All technical indicators fully meet the standard DL/T624-1997: Technical condition of the relay computer test device.* Classic Windows XP operating interface, friendly man-machine interface, easy and fast to operate; High-performance embedded industrial control computer and 8.4 inch 8.4 - inch resolution of 800 × 600 TFT true color display which provides rich visual information, includes the current working condition and all kinds of help information.
* The Windows XP system comes with the restore function; avoid system crashes caused due to illegal shutdown, or malfunction, etc.
* Equipped with ultra-thin industrial keyboard and optical mouse, complete a variety of operations using keyboard or mouse the same as ordinary PC.
* The main control board is DSP + FPGA architecture, 16 bit DAC output, generates high - density sine wave 2000 points each circle to fundamental wave, which greatly improve the wave quality and the accuracy of the test instrument.
* Using high-fidelity linear amplifier. Both to ensure the accuracy of a low current, but also guarantee the stability of the high current.
* USB directly connect with PC, without any adapter cable, easy to use.
* Can be connected to a laptop computer (optional).Laptop computers and industrial machines use the same software, no need to re-learn the methods of operation.
* With GPS synchronization test function. The device can be built-in GPS synchronization card (optional) connects with PC by RS232; people can do remote synchronization swap test for the two testers.
* With a separate DC auxiliary voltage source, output voltage 110V(1A),220V(0.6A), provides relays or protective devices which require DC power.
* The software with self calibrating function, which avoid to calibrate accuracy by adjusting relays after open the case, greatly improve the stability of the accuracy.
2.Technique parameters
1. AC current source (3*30A)
Single-phase current output (valid value) |
0--30A/phase, accuracy: 0.2% ±5mA |
Three-phase parallel output (valid value) |
0--90A/three identical phase parallel output |
Allowable working value of phase current for a long time (valid value) |
10A |
Maximum output power per phase |
300VA |
Maximum output power of three-phase parallel current |
800VA |
Maximum output of three-merging current allows working hours. |
5Small size |
Frequency range |
0--1000Hz, accuracy 0.001Hz |
Number of harmonics |
2--20 times |
Phase |
0--360°, Accuracy 0.1° |
2. DC current source
DC current output |
0--±10A/phase, accuracy: 0.5% ±5mA |
3. AC voltage source
Single-phase voltage output (effective value) |
0--120V/phase, accuracy: 0.2% ±5mV |
Line voltage output (valid value) |
0--240V |
Phase voltage/line voltage output power |
75VA/100VA |
Frequency range |
0--1000Hz, accuracy: 0.001Hz |
Number of harmonics |
2--20 times |
Phase |
0--360°Accuracy: 0.1° |
4. DC voltage source
Single-phase voltage output amplitude |
0--±160V, accuracy: 0.2% ±5mV |
Line voltage output amplitude |
0--±320V |
Phase voltage/line voltage output power |
90VA/180VA |
5. Switching terminal
Switching input terminals |
8 pairs |
Empty contacts |
1--20mA, 24V device internal active output |
Potential flipping |
Passive contact: low resistance short connection signal Active contact: 0-250V DC |
Switching output terminal |
4 pairs, empty contacts, blocking capacity: 110V/2A, 220V/1A |
6. Other
Time frame |
1ms-9999s, measurement accuracy: 1ms |
Single unit volume weight |
Volume 328 x 168 x 250mm3, about 12.5Kg |
Power supply |
AC220V±10%, 50Hz, 10A |
7. AC current working hours
10A≥Operating current |
Working time >60 minutes |
20A≥Operating current≥10A |
Working hours >70S |
30A≥Operating current≥20A |
Working hours >15S |
Operating current≥30A |
Working hours >5S |